| VISTA-100
Key Features
- Eight
zones standard expandable to 87 zones/points
- Eight
partitions
- 150 user
codes, 224 event log capacity
- Two on-board
notification (bell) circuits delivering 2.3A at 12V or 3.4A at 24V (optional)
- Supports
in excess of 1,000 two-wire smoke detectors
- Seven
authority levels
- Temporal
code compliant
- Supports
UL268 Listed commercial wireless smoke detectors
- Supervised
dialer circuit
- Event
logging storage, printing and retrieval
- Automatic
scheduling features
- Easily
programmed and maintained through Compass WindowsT based software
- Programmable
auxiliary Form C relay
- Hardwired,
wireless and V-Plex (addressable) technology
- Uses existing
wiring for retrofit applications
Additional
Features
- Notification
Appliance Circuits (Two)
- Programmable
- Temporal code compliant
- Individually silenceable
- Programmable
on-board auxiliary relay
- SIA false
alarm reduction features:
- Exit error logic
- Exit delay reset
- Cross zoning
- Call waiting defeat
- Recent close report
- Supports
hardwired, V-Plex (addressable) polling loop and wireless zones
- Hardwired
zones
- Provides eight style B hardwired zones
- EOLR supervised for Fire and UL burglary installations
- Supports N.O. or N.C. sensors
- Individually assignable to one or all eight partitions
- Up to 16 two-wire smoke detectors on zones one and two (32 total)
- Four-wire smoke or heat detectors on zones one to eight
- Up to 50 two-wire glass break detectors on zone eight
- Patented
V-Plex (addressable) polling loop technology
- Supports up to 120 two-wire multiplex zones/points
- Can use existing wiring
- Global polling technology for faster processing
- Increased current draw capacity (128mA)
- Individually assignable to partitions, notification circuit (bell)
output or aux relay
- 4,000 ft capability without the use of shielded cable
- Extender/Isolation bus module
- Two-wire smoke detector zone/group expansion module adds two or four
zones
- Eight zone - Class A and B extender module
- Eight zone - Class B extender module
- One zone supervised contact monitor module
- UL Listed
wireless smoke detector expansion
- Supports up to 87 wireless zones using 5881 receiver
- Supervised by control for check-in signals
- Tamper protection for transmitters
- Individually assignable up to eight partitions
- Supports UL864/NFPA listed/complaint wireless smoke detectors
- Scheduled
uploading of events to central station
Applications
The
VISTA-100 control is well suited for a variety of applications as an integrated
fire and burglary control. A diverse line of ADEMCO initiating and control
devices supports this extremely powerful control. Some of the applications
supported are: medical and professional buildings, supermarkets, churches
or synagogues, office buildings, schools, universities, strip malls, and
factory or warehouse environments.
Installation
The
VISTA-100 alarm system has been designed to mount both quickly and easily
in an attack resistant cabinet. It meets all applicable requirements for
UL commercial Fire and Burglary installations and is NFPA72 compliant.
DIAGRAM

Specifications
ELECTRICAL
Primary
Power
-
120VAC to ADEMCO No. 1451 Transformer Secondary rated 18VAC, 72VA
Quiescent
Current Draw:
-
350mA
Backup
Battery:
-
12VDC, 12AH min to 34.4AH max
- Lead acid battery (gel type)
Alarm
Power:
-
12VDC, 1.7A max for each notification (bell) circuit output
Aux.
Standby Power:
-
12VDC, 1A max
Total
Power:
-
2.3A at 12VDC, 3.4A at 24VDC from all sources
Standby
Time:
-
24 hours with 1A standby load or 60 hours with 205mA max standby load
using 34.4AH battery
Fusing:
-
Battery input, aux. and notification (bell) circuit outputs are protected
using PTC circuit protectors. All outputs are power limited
Main
Dialer:
Line
Seize:
-
Double Pole
Ringer
Equiv.:
-
0.7B
Formats:
-
ADEMCO Low Speed, ADEMCO 4+2 Express, ADEMCO High Speed, ADEMCO Contact
ID, Sescoa and Radionics
Mechanical
Cabinet
Dimensions
Environmental
Storage
temp
Operating
temp
Humidity
EMI
- Meets
or exceeds the following requirements:
- FCC Part
15, Class B Device
- FCC Part
68
- IEC EMC
Directive
Agency
Listings
Burglary
- UL609
Grade A Local Mercantile Premises and Mercantile Safe and Vault
- UL611/1610
Grades A, AA, Central Station
- UL365
Grades A, AA Police Connect
Fire
- UL864/NFPA72
Local, Central Station and Remote Station
- Factory
Mutual (Pending)
- California
State Fire Marshal
- MEA
- UL985
COMPATIBLE
DEVICES
See
ADEMCO Group control accessories compatibility chart for complete list
Auxiliary
devices:
-
6139R
- Red Alpha Keypad/Annunciator
-
5140DLM
- Backup Dialer Module
-
5140LED
- LED Annunciator Module
-
4204
- Relay Module, four Form C contacts
- 4204CF
- Two supervised output circuits
- 5881 EH
- RF Receiver supporting 5800 wireless detectors
- 6220S
- System Printer used with 4100SM Serial Module
Two-wire
Smoke Detectors Conventional:
- 2100 Series
Photoelectric
- 2400 Series
Photoelectric
- 1100 Series
Ionization
Four-Wire
Smoke Detectors Conventional:
- 2112/24
Series Photoelectric
- 1412 Series
Ionization
Horn/Strobes:
- System
Sensor Notification Appliances
Manual
Pull Stations:
V-Plex
(addressable) Devices:
- 4101SN
Single Relay /Zone Module
- 4190WH
Remote Point Module - two zones
- 4193SN
Two Zone Serial Interface Module
- 4208U
Loop Expansion Module - eight zones
- 4208SNF
Eight Zone/2 Class A/6 Class B Expander Module
- 4209U
Group Zoning Module - two/four zones
- 4293SN
One Zone Serial Interface Module
- 4297 Isolation/Extender
Module
V-Plex
(addressable) Smoke Detectors:
Passive
Infrared Detectors:
V-Plex
(addressable) Contacts:
- 4194WH
- 4939SN
- 4944SN
- 4959SN
Glassbreak
Detectors:
Optional
24V Power Supply
- PS24
- 24V power supply - 3.4A
Long
Range Radio:
Upgraded
Software:
- Upgraded
Compass Downloader WindowsT compatible
Wireless
Devices:
- 5804 -
Wireless Key
- 5804BD
- Bi-Directional Key
- 5808 -
Wireless Smoke Detector
- 5808C
- Wireless Smoke Detector without sounder
- 5809 -
Wireless Heat Detector
- 5816 -
Door/Window Transmitter
- 5819 -
Shock Sensor
- 5827BD
- Bi-Directional Keypad
- 5849 -
Glassbreak Detector
- 5890 -
PIR
All