Dependable
features to meet your most demanding installations:
- Six hardwired
zones standard
- Expands
to 22 total zones when using 5800 wireless
- Seven
user codes
- Two-method
downloading
- Supports
up to four relays
- False
alarm prevention features
- Fast and
easy E2 programming mode
End
users will appreciate the easy-to-use convenience and control features
of the VISTA-10SE:
Specifications
Electrical
- 500
mA, Aux - 12 VDC
- 16.5
VAC/25 VA transformer
- Alarm
output 12 VDC, 2.0 amps max
- For
UL installations, combined Aux and alarm
output cannot exceed 600mA
Output
Control
- Supports
one relay board (part number
4204)
for four relays
Zones
- Six
hardwired zones
- Selectable response: 10msec, 350msec,
750msec
- Expandable to 22 zones using 5800
wireless
- 16 zone types to choose from
- Programmable swinger suppression
Supported
Devices
Hardwired
Expansion Devices
-
4204 supports up to four relays-15mA standby
(each active relay draws an additional
40mA)
- Keypads
- 6160/6139 Custom English (required for programming)
- 150mA/40mA, 100mA/40mA
- 6150/6128 Fixed English LCD - 70mA/40mA, 40mA/20mA
-
4286 VIP Voice Module - 220mA
- Four-wire
smoke detectors
Wireless
Receiver Systems
- 5800
receivers
- 5881ENL up to 8 zones - 60mA
- 5881ENM up to 16 zones - 60mA
- All
receivers support
- Diversity reception with two antennae
- Remote mounting for best location
- Unique supervision and low battery indications
by point
Transmitters
- 5800
Series
- Three-Volt Duracell lithium batteries
- One mile range
- Tamper is standard
Agency
Listings
UL
Residential Fire and Burglary and CFM
Communications
- Touchtone
or pulse
- Formats
supported
- ADEMCO Contact ID
- ADEMCO 4 + 2 Express
- ADEMCO Low Speed
- Sescoa/Radionics
- 3
+ 1, 4 + 1 and 4 + 2 reporting
- Reporting
capabilities: Split, Dual, Split/Dual,
Pager
|