FEATURES
- Provides
nine style-B hardwired zones
- Supports
up to 119 additional zones using a built-in polling (multiplex) loop
interface
- Can control
up to eight separate partitions independently, each functioning as if
it had its own separate control
- Accommodates
150 user codes with seven authority levels
- Supports
up to 128 wireless zones using a 5881 type RF receiver (fewer if using
hardwired and/or polling loop zones)
- Supports
the 5817CB Wireless Commercial Transmitter
- Supports
the 5869 Wireless Commercial Burglary Hold-up switch
- Supports
the 5881ENHC Wireless Commercial receiver
- Accommodates
32 keypad macro commands per system
- Keeps
a log of up to 512 events
- Supports
up to 16 two-wire smoke detectors on zone 1
- Supports
up to 50 latching-type glassbreak detectors on zone 8
- Integrates
with PassPoint access control to provide increased users, event log,
and scheduling
- Supports
V-Plex addressable VistaKey access control (up to 8 doors)
- Easily
programmed and maintained using Compass Windows-based downloader
- Supports
the ADEMCO 4286 VIP Module
Additional
Features
Basic
Hardwired Zones
Provides nine style-B hardwired zones with the following characteristics:
-
EOLR
supervision (optional for zones 2-8) supporting N.O. or N.C. sensors
(EOLR supervision required for fire and UL burglary installations)
-
Individually
assignable to one of eight partitions
-
Up
to 16 two-wire smoke detectors on zone 1
-
Four-wire
smoke or heat detectors on zones 1-8 (power to four-wire smoke detectors
must be supervised with an EOL device)
-
Up
to 50 two-wire latching glassbreak detectors on zone 8
Polling
Loop Expansion
Supports up to 119 additional zones using a built-in polling (multiplex)
loop interface. Current draw can total up to 128mA. Polling loop zones
have the following characteristics:
-
Must
use RPM (Remote Point Module) devices
-
Supervised
by control panel
-
Individually
assignable to one of eight partitions
Wireless
Expansion
Supports up to 128 wireless zones using 5881 type RF receiver (fewer
if using hardwire and/or polling loop zones). Wireless zones have the
following characteristics:
-
Supervised
by control panel for check-in signals (except certain non-supervised
transmitters)
-
Tamper
protection for supervised transmitters
-
Individually
assignable to one of eight partitions
Scheduling
Provides the following scheduling capabilities:
-
Open/close
schedules (for control of arming/disarming and reporting)
-
Holiday
schedules (allows different time windows for open/close schedules)
-
Timed
events (for activation of relays, auto-bypassing and unbypassing,
auto-arming and disarming, etc.)
-
Access
schedules (for limiting system access to users by time)
-
End
User Output Programming Mode (provides 20 timers for relay control)
Eight
Partitions
Provides the ability to control eight separate areas independently,
each functioning as if it had its own separate control. Partitioning features
include:
- A Common
Lobby partition (1-8), which can be programmed to arm automatically
when the last partition that shares the common lobby is armed and to
disarm when the first partition that shares the common lobby is disarmed
- A Master
partition (9), used strictly to assign keypads for the purpose of viewing
the status of all eight partitions at the same time (master keypads)
- All zones
assignable to one of eight partitions
- Keypads
assignable to one of eight partitions or to master partition 9 to view
system status
- Ability
to assign relays to one or all eight partitions
- Ability
to display fire and/or burglary and panic and/or trouble conditions
at all other partitions' keypads (selectable option)
- Certain
system options selectable for each partition, such as entry/exit delay
and subscriber account number
User
Codes
Accommodates 150 user codes, all of which can operate any or all partitions.
Certain characteristics must be assigned to each user code, which are
as follows:
- Authority
level (Master, Manager, or several other Operator levels) in each partition
- Opening/Closing
central station reporting option
- What partitions
the code can operate
- Global
arming capability (ability to arm all partitions the code has access
to in one command)
- Use of
an RF (button) to arm and disarm the system (RF key must first be enrolled
into the system)
Peripheral
Devices
Supports up to 31 peripheral devices, which can be any combination
of keypads (6139/6160), RF receivers (5881), relay modules (4204/4204CF),
and 4286 VIP Module.
At
least one two-line alpha keypad (6139/6160) must be connected to the system
for programming (if using keypad programming) and must remain connected
to the system in order to allow the primary user to program additional
user codes into the system at a later time.
Keypad
Macros
Accommodates 32 keypad macro commands per system (each macro is a
series of keypad commands). For example, by pressing either the A, B,
C, or D key, the system can be programmed to log onto another partition,
bypass Zones 2 and 3, and arm that partition in the AWAY mode. Characteristics
of keypad macros are:
- Assignable
to the A, B, and C keys by partition
- Other
macros, (not assigned to these keys) executed by using the D key
- Each macro
can be 32 characters (keystrokes) in length
Optional
Output Relays
Accommodates the use of 96 relay outputs using ADEMCO's 4204, 4204CF
Relay Modules and 4101SN V-Plex Relay Module. Each 4204 module provides
four Form C relays for general purpose use. Each 4204CF provides two style-Y
supervised bell outputs. Relay outputs have the following characteristics:
- Can be
programmed to activate in response to system events
- Can be
programmed to activate using time intervals
- Can be
used for style-Y supervised bell outputs (4204CF only)
- Can be
activated manually using the #70 Relay Command Mode
- Can be
supervised by control panel (zones 601-632)
- Can each
have an alpha descriptor assigned to it
Optional
VISTA Interactive Phone Module
Supports the ADEMCO 4286 VIP Module. This permits access to the security
system from a touch tone telephone to do the following:
- Obtain
system status information
- Arm and
disarm security system
- Control
relays
Optional
Keyswitch
Supports the ADEMCO 4146 Keyswitch on any one of the system's eight
partitions. If used, zone 7 is no longer available as a protection zone.
Voltage
Triggers
Provides a trigger connector whose pins change state for different
conditions. Used with LRR (Long Range Radio) equipment or other devices
such as a remote keypad sounder, keyswitch ARMED and READY LEDs, or a
printer to print the system's event log.
Event
Log
Keeps a log of different event types (enabled in programming). The
event log has the following characteristics:
- Stores
up to 512 events
- Can be
viewed at the keypad or through the use of Compass software
- Can be
printed on a serial printer using a 4100SM Module including zone alpha
descriptors
- Events
can be sent to an alpha numeric pager, by event category
Cross-Zoning
Capability
Helps prevent false alarms by preventing burglary zones from going
into alarm unless its cross-zone is also faulted within five minutes.
Exit
Error False Alarm Prevention Feature
- System
can tell the difference between a regular alarm and an alarm caused
by leaving an entry/exit door open. If not subsequently disarmed, faulted
E/E zone (s) and/or interior zones will be bypassed and the system will
arm
- Generates
an Exit Error report by user and by zone so the central station knows
it was an exit alarm and who caused it
Communication
Formats
Supports the following formats for the primary and secondary central
station receivers:
- ADEMCO
Low Speed (Standard or Expanded)
- ADEMCO
High Speed
- ADEMCO
Contact ID
- Sescoa/Radionics
- Long Range
Radio interface (ECP)
- ADEMCO
Express
Improved
Downloading Features
- Uploads
and downloads at 300 baud, making upload/download speed faster
- Ability
to upload peripheral devices, their physical addresses, programmed addresses,
and firmware revision levels from the control
CCTV:
Switcher Module
Access
Control
- VistaKey
(addressable) Access Control Module
- VistaKey-SK
Starter Kit (Canada use VistaKey CNSK)
- VistaKey-EX
Expansion Kit
- VGM Vista
Gateway Module to PassPoint Access Control (Northern Computers) supports
up to 32 doors
Agency
Listings
*
Requires VISTA-ULKT Attack Resistant Enclosure
DIAGRAM

SPECIFICATIONS
Physical:
14-1/2"
W X 18" H X 4.3" D
Electrical:
-
Voltage
Input: From ADEMCO No. 1361 Plug-In Transformer (use 1361CN in
Canada) or 4300 transformer (for X-10 installations) rated 16.5VAC,
40 VA (For Canada use 1361CN transformer w/PSC04 for X-10 installations)
-
Alarm
Sounder Output: 10VDC-13.8VDC, 1.7 amps max., (UL1023, UL609 installations);
750mA less aux. current draw (UL985 installations)
-
Auxiliary
Power Output: 9.6VDC-13.8VDC, 750mA max. For UL installations,
the accessories connected to the output must be UL Listed, and rated
to operate in the above voltage range
-
Backup
Battery: 12VDC, 4AH or 7AH gel cell. YUASA NP4-12 (12V, 4AH) or
NP7-12 (12V, 7AH) recommended
-
Standby
Time: 4 hours min. with 750 mA aux. load using 7 AH battery
-
Circuit
Protectors: PTC circuit breakers are used on battery input to
protect against reverse battery connections and on alarm sounder output
to protect against wiring faults (shorts). A solid state circuit breaker
is used on auxiliary power output to protect against wiring faults
(shorts)
Digital
Communicator
-
Formats
Supported: ADEMCO High Speed, ADEMCO 4 + 2 Express, ADEMCO Low
Speed, ADEMCO Contact ID, Sescoa and Radionics Low Speed
Line
Seize: Double Pole
Ringer
Equivalence: 0.7B
FCC
Registration No.: AC398U-68192-AL-E
IC
Industry Canada
6139
Remote Keypads/6160 Alpha Keypad
-
Physical:
- Width: 6.25 inches
- Height 4.75 inches
- Depth: 1.25 inches
-
Electrical:
- Voltage Input: 12VDC
- Current Drain: 100 mA
-
Interface
Wiring:
- RED: 12VDC input (+) auxiliary power
- BLUE: Not used
- GREEN: Data to control panel
- YELLOW: Data from control panel
- BLACK: Ground and (-) connection from supplemental power supply
Optional
Equipment:
See
ADEMCO Group control accessories compatibility chart for complete list.
- 4100APG
Alpha Paging
- 7845C
AlarmNet Control Channel Cellular Radio
- 7820
Long Range Radio (7830RCN in Canada)
- 4286
VIP Module
- 5881
RF Receivers
- Powerline
carrier devices
- 6220S
Serial Printer
|