| Vista
128BP
Users Manual PDF >>>
Installation Manual PDF >>>
FEATURES
-
Provides
nine style-B hardwired zones
-
Supports
up to 119 additional zones using a built-in polling (multiplex) loop
interface
-
Supports
up to 128 wireless zones using 5881 type RF receiver (fewer if using
hardwired and/or polling loop zones)
-
Provides
one power-limited bell circuit delivering 1.7Amp (max) at 12Vdc.
-
Provides
the ability to control eight separate partitions independently, each
functioning as if it had its own separate control
-
Accommodates
150 user codes with seven authority levels
-
Accommodates
32 keypad macro commands per system
-
Keeps
a log of up to 512 events
-
VistaView-100
CCTV support
-
Supports
up to 16 two-wire smoke detectors on zone 1
-
Supports
up to 50 latching-type glassbreak detectors on zone 8
-
Zone
7 may be used for keyswitch arming/disarming
-
Integrates
with PassPoint access control systems to provide increased users,
event log, and scheduling (up to 32 doors)
-
Supports
V-Plex addressable VistaKey access control (up to eight doors and
250 cards)
-
Easily
programmed and maintained by the newly upgraded Compass Windows-based
downloader
-
Supports
up to 96 programmable relays
-
Supports
the ADEMCO 4286 VIP Module
-
False
alarm reduction features
New
Enhancement:
-
up to eight panels
- Two-Way
RS232 (facility automation software support) optional
- Supports
eight numeric pager numbers
- Supports
touch screen Advanced User Interface (AUI) (Future)
- Smoke
Detector Reset at keypad
- QUICK
EXIT
- Group
Bypass
- Arm Faulted
- Event
Arming
- Scheduled
check-in
- ARM STAY
by group
Additional
Features
Basic
Hardwired Zones
Provides
nine style-B hardwired zones with the following characteristics:
- EOLR
supervision (optional for zones 2-8) supporting N.O. or N.C. sensors
(EOLR supervision required for fire and UL burglary installations)
- Individually
assignable to one of eight partitions
- Up to
16 two-wire smoke detectors on zone 1
- Four-wire
smoke or heat detectors on zones 1-8 (power to four-wire smoke detectors
must be supervised with an EOL device)
- Up to
50 two-wire latching glassbreak detectors on zone 8
Polling
Loop Expansion
Supports
up to 119 additional zones using a built-in polling (multiplex) loop interface.
Current draw can total up to 128mA. Polling loop zones have the following
characteristics:
- Must
use RPM (Remote Point Module) devices
- Supervised
by control panel
- Individually
assignable to one of eight partitions
Wireless
Expansion
Supports
up to 128 wireless zones using 5881 RF receiver (fewer if using hardwire
and/or polling loop zones). Wireless zones have the following characteristics:
- Supervised
by control panel for check-in signals (except certain non-supervised
transmitters)
- Tamper
protection for supervised transmitters
- Individually
assignable to one of eight partitions
Scheduling
Provides
the following scheduling capabilities:
- Open/close
schedules (for control of arming/disarming and reporting)
- Holiday
schedules (allows different time windows for open/close schedules)
- Timed
events (for activation of relays, auto-bypassing and unbypassing, auto-arming
and disarming, etc.)
- Access
schedules (for limiting system access to users by time)
- End user
output programming mode (provides 20 timers for relay control)
Eight
Partitions
Provides
the ability to control eight separate areas independently, each functioning
as if it had its own separate control. Partitioning features include:
- A Common
Lobby partition (1-8), which can be programmed to arm automatically
when the last partition that shares the common lobby is armed and to
disarm when the first partition that shares the common lobby is disarmed
- A Master
partition (9), used strictly to assign keypads for the purpose of viewing
the status of all eight partitions at the same time (master keypads)
- All zones
assignable to one of eight partitions
- Keypads
assignable to one of eight partitions or to master partition 9 to view
system status
- Ability
to assign relays to one or all eight partitions
- Ability
to display fire and/or burglary and panic and/or trouble conditions
at all other partitions' keypads (selectable option)
- Certain
system options selectable for each partition, such as entry/exit delay
and subscriber account number
New Enhancement 
-
allows multiple control panels to be networked together and controlled
from any keypad in the system:
- Control
multiple zones, partitions, buildings from a central location
- Check
status, arm and disarm any partition from any keypad in the system (based
on user's authority level)
- Users
can have a different authority level in each partition and access to
different partitions in each panel
- Global
Arming - users can arm and disarm all the partitions in all the panels
they have access to, with one set of keystrokes
Applications
The
VISTA-128BP control is well suited for a variety of applications as a
burglary control and is supported by a diverse line of ADEMCO initiating
devices. Applications include medical and professional buildings, supermarkets,
churches or synagogues, office buildings, schools, universities, strip
malls, larger residences and factory or warehouse environments.
Installation
The
VISTA-128BP alarm system has been designed to mount both quickly and easily.
It meets all applicable requirements for UL-Commercial Burglary installations,
use the Vista-ULKT kit when an attack resistant enclosure is required.
Agency
Listings Burglary
- UL609
Grade A Local Mercantile Premises and Mercantile Safe and Vault
- UL611/UL1610
Grades A, AA Central Station
- UL365
Grades A, AA Police Connect
- UL985
Household Fire
- California
State Fire Marshall (CSFM)
- UL listing
1023 - Household Burglar Alarm
DIAGRAM

SPECIFICATIONS
Electrical:
- Voltage
Input: From ADEMCO No. 1361 Plug-In Transformer (use 1361CN in Canada)
or 4300 transformer (for X-10 installations) rated 16.5VAC, 40 VA
- Alarm
Sounder Output: 10VDC-13.8VDC, 1.7 amps max., (UL1023, UL609 installations);
750mA less aux. current draw (UL985 installations)
- Auxiliary
Power Output: 9.6VDC-13.8VDC, 750mA max. For UL installations, the accessories
connected to the output must be UL Listed, and rated to operate in the
above voltage range
- Backup
Battery: 12VDC, 4AH or 7AH gel cell. YUASA NP4-12 (12V, 4AH) or NP7-12
(12V, 7AH) recommended
- Standby
Time: 4 hours min. with 750 mA aux. load using 7 AH battery
- Circuit
Protectors: PTC circuit breakers are used on battery input to protect
against reverse battery connections and on alarm sounder output to protect
against wiring faults (shorts). A solid state circuit breaker is used
on auxiliary power output to protect against wiring faults (shorts)
Main
Dialer:
- Formats
Supported: ADEMCO High Speed, ADEMCO 4 + 2 Express, ADEMCO Low Speed,
ADEMCO Contact ID, Sescoa and Radionics Low Speed
- Line Seize:
Double Pole
- Ringer
Equivalence: 0.7B
Cabinet
dimensions:
12-1/2"
W X 14-1/2" H X 3" D
COMPATIBLE
DEVICES
See
ADEMCO Group control accessories compatibility chart for complete list
Auxiliary
devices:
Two-wire
Smoke Detectors Conventional:
- System
Sensor smoke detectors
Horn/Strobes:
- System
Sensor Notification Appliances
Manual
Pull Stations:
V-Plex
(addressable) Devices:
- 4101SN
Single Relay /Zone Module
- 4190SN
Remote Point Module - two zones
- 4193SN
Two Zone Serial Interface Module
- 4208U
Loop Expansion Module - eight zones
- 4208SNF
Class A/B Expander Module
- 4209U
Group Zoning Module - two/four zones
- 4293SN
One Zone Serial Interface Module
- 4297 Isolation/Extender
Module
V-Plex
(addressable) Smoke Detectors:
Passive
Infrared Detectors:
- 998MX
- 4275EX-SN
- 4287EX-SN
- QUEST2260SN
V-Plex
(addressable) Contacts:
- 4939SN-WH
- 4944SN-WH
- 4959SN,
9500SN
Glassbreak
Detectors:
VISTA
Interactive Phone Module
Long
Range Radio:
Upgraded
Software:
- Upgraded
Compass Downloader WindowsT compatible
Wireless
Devices:
-
5804
- Wireless Key
- 5804BD
- Bi-Directional Key
- 5804BDV
- Bi-Directional with voice
- 5804Watch
- Wireless Key and full featured sports watch
- 5816 -
Door/Window Transmitter
- 5819 -
Shock Sensor
- 5827BD
- Bi-Directional Keypad
- 5849 -
Glassbreak Detector
- 5890 -
PIR
Access
Control:
- VistaKey
V-PLEX (addressable) Access Control
- VistaKey-SK
Starter Kit
- VistaKey-EX
Expansion Kit
- VGM Vista
Gateway Module to PassPoint Access Control (Northern Computers)
CCTV
- CCTV -
VistaView-100 CCTV Switcher Module
Commercial
WIreless Dev ices:
- 5808LST
- Wireless Smoke Detector**
- 5809 -
Wireless Heat Detector
- 5817CB
- Commercial UL Burglary, Universal Contact Monitoring Transmitter*
- 5869
- Commercial UL Wireless Hold-up Button*
- 5881ENHC
*When used with 5881ENHC Receiver.
**Not listed for commercial use with the VISTA-128BP, residential listing
only.
|