MEMBER OF:
CANASA
Bulgarian Chamber of Commerce and Industry
Bulgarian Alarm Systems Assotiation
About Us
DOWNLOADS
What's new
Home Audio
cctv camera
New Definitive Technology speakers
Get more information here >>>

 Features | Zones | Wireless Operation | Partitions | Outputs | User Codes | Additional Features | SmartLogT
 Keypads
| Programming/Remote Operations | Central Station Communications | Power Specifications | Listings

Ordering Information


Users Guide PDF >>>
Installation Guide PDF >>>

Features:

  • Six zones expandable to 24 zones

  • Six fully programmable wired zones (12 zones with our unique zone doubling option)

  • 14 fully programmable wired zones with our OMNIEXP8 - Eight Hardwired Zone Expander (24 zones with our unique zone doubling option)

  • 24 total zones with wireless

  • Operates with FBII International or ADEMCO wireless devices

  • Supports eight four-button wireless keys without taking up any zones

  • Four totally programmable trigger outputs on board

  • Up to 20 fully programmable relay outputs

  • Two partitions

  • System Log retains the past 128 Events - New selectable SmartLog

  • 32 user codes with four authorization levels

  • AUTO ARMING

  • Tamper option by zone

  • Built-in telephone line monitor

  • Zones may be configured as wired, wireless, E.O.L., D.E.O.L., N.O., N.C. or zone doubling

  • Follow Me (Beeps audio format), domestic dialing

  • Paging

  • Inactivity zones

  • New smaller cabinet: 10"H x 10"W x 4"D

Zones:
(Return to top)

  • Six fully programmable EOL or DEOL supervised wired zones on main board (up to 12 N.C. wired zones with our unique zone doubling option)

  • Expansion through plug in modules OPTIONS: Model OMNIEXP8 (Eight Zone Wired Expander), OMNI-RF (868MHz), ZR402EU (433MHz), ZR401 (345 MHz) wireless receivers

  • 14 traditional EOL or DEOL supervised wired zones with OMNIEXP8 zone expander module (up to 24 N.C. wired zones with our unique zone doubling option)

  • Zones five and six may be programmed as fast zones (10 msec)

  • Zone programming selectable as EOL, DEOL, Zone Doubling, NO, NC

  • Four emergency keypad conditions (Fire, Panic, Personal Emergency, Duress)

  • Versatile Zone Types:
    - Controlled zone types include: instant, exit/entry, interior, day, and keyswitch, with options for fast loop response (zones 5 and 6), restore, chime, bypass and dialer delay by zone
    - 24 Hour Zone Types include: Fire, Burglary, Silent, Trouble, and Medical

  • Programmable central station reporting codes per zone . Individual reporting codes for Ambush, Panic, AC Loss, 24 Hour Test, Low Battery, Open/ Close, Trouble, Restore . Cross zoning

  • Stay Delay Mode provides an additional 40 seconds of dialer and/or siren delay for special interior zones when armed in the stay mode

  • Arm while a zone is faulted option

  • Restore options: after siren time-out or follows loop

  • Keyswitch option per zone

  • Chime option by zone

  • Inactivity option by partition transmits signal to C.S. if zones have not been activated in a preset time

Wireless Operation:
(Return to top)

  • 24 zone wireless receiver attaches directly to PCB

  • Compatible with FBII International or ADEMCO wireless peripherals

  • Dual diversity antenna

  • Fully supervised wireless displays complete zone status, low battery and RF trouble by zone on all keypads

  • System supports eight wireless keys with each button individually programmable. Additionally, each button can activate triggers/relays

  • Wireless remote keyfob transmits Open/Close ID's for each remote

  • Separate RF dings for arming and disarming with remote keys

Outputs:
(Return to top)

  • Supports up to 20 relays per system (five per XL4705 External Relay Module)

  • Relays and triggers can be linked to zones, wireless remote keyfobs, keypad emergency and system conditions

  • Select time duration for momentary conditions

Partitions:

  • Two partitions

  • Zones, user codes, keypads, and remote keyfobs may be assigned to each partition

  • Extensive cross partition support

  • Separate account and pager numbers for each partition

  • Auto arming by partition

  • Inactivity zones programmable by partition

  • View all partitions from a single keypad

  • Partition descriptor uniquely identifies each partition

  • Multi Partition mode allows secure operation of the system through any keypad by authorized users

  • Arm/disarm all partitions through a single keypad by authorized user

  • Partition Status keypad mode

User Codes:

  • 32 user codes, with four authorization levels

  • Four or six digit user codes

  • Programmable Open/Close ID's for each user

  • Option to transmit O/C signals by user

  • Ambush/Duress and Door Strike codes

  • QUICK ARMING, QUICK FORCED ARMING, QUICK BYPASS, QUICK EXIT options

  • Arm only code

  • Paging option by user

Additional Features:
(Return to top)

  • Cancel code feature, with siren verify option

  • Dual entry delay timers

  • Installer walk test feature

  • Telephone line monitor

  • Real time clock with reminder when time needs to be reset

  • Siren Test option, Smoke Detector Reset and Verification options

  • Separate alarm cutoff times for BURG and FIRE siren Programmable entry/delay times, and siren lockout feature

  • Intermittent sensor shutdown option

  • AC or crystal based real time clock (50/60hz selectable)

  • Siren supervision

  • End user chime selection

  • System stabilization mode prevents false alarms during power-up

  • Recent close and exit error options

  • Keypad tamper function with optional C.S. transmission

  • Keypad lockout option

  • QUICK EXIT

  • Arm while a zone is faulted

  • Option to display zone status upon entry delay

  • Programmable dialer attempts programmable between 1-16

  • LED Extinguish option

  • AC/LB sounder disable option

  • Display bypassed zones during armed state

  • Chime on/off option through keypad

  • Single key arming options by pressing either the "Stay" or "Instant" key on all FBII keypads, or by using the Chatbak-V or wireless remotes

  • AUTO STAY option

  • AUTO UNBYPASS option

  • Flexible system test timers (1, 7, 27, 60, 90 days) with options for test by time, event or both. Additional one hour test time option for high security applications

SmartLogT:

  • FBII's unique SmartLog option allows you to choose the events to be stored in memory

  • Panel retains past 128 events

  • 90% or 100% full indication of system log transmitted to C.S.

  • System log viewable locally at LCD keypad or uploaded to Alarm Company

  • Date (DD/MM or MM/DD) and time (24 hour or AM/PM) option

  • End-user log view option

Keypads
(Return to top)

  • Supports up to eight keypads per system (LED, fixed word LCD, and custom language programmable LCD)

  • LED keypad displays status of each individual zone, with indications of ALARM, TROUBLE, TAMPER, STAY, BYPASS, INSTANT, POWER and NOT READY conditions

  • Fixed word LCD keypad displays status of each zone, with indications of ALARM, FIRE, TROUBLE, TAMPER, BYPASS, PAGE, RF SUPERVISION, CANCELED, CHIME, PHONE, TEST, AC, BATTERY, and NOT READY conditions

  • Custom language LCD keypads display complete system status, in 2 line by 16 character Supertwist display for easy viewing

  • All keypads available in many languages. Please contact your nearest distributor for details

Programming/Remote Operations:

  • On-site programming directly through keypads

  • Remote programming through WindowsT Downloader

  • Security features include special CSID and Installer codes, callback number, default lockout feature and option to inhibit keypad programming

  • Online and unattended downloading

  • Up/Download remotely even in the presence of fax/answering machines

  • Remote operations can be performed through single or a two call method

  • Remote operations include: arm, disarm, bypass zones, change user codes, read system status, view event log and more

Central Station Communications:
(Return to top)

  • Two CS account numbers (3 or 4 digits)

  • Pulse or DTMF dialing options

  • Pulse formats include 3x1, 4x1, 4x2, Expanded: Speeds 10, 20, 40PPS with or without parity

  • FBII Superfast, ADEMCO Express 4x1, and 4x2 formats, ADEMCO CID format

  • Split and Dual reporting option

  • Sonalert ringback feature

  • Follow me (domestic dialing), paging, beeps audio formats

Power Specifications:

  • Watchdog circuitry insures integrity of microprocessor

  • Total Aux. power: 500mA. regulated

  • Transformer: 16.5V 25VA

  • Alarm Power: 1 Amp

Listings:
(Return to top)

  • CE, TBR21, Austel, ANPI, and IMQ

  • Pending UL, Norway and Sweden

Ordering Information

 
Ademco
FBII
Panasonic
Bosch Sound Systems
Soyal
Viper
Whistler
escort detectors
Orion
Parasound
 
 
 