Features:
- 8 zones
expandable to 48 zones
- Eight
Fully programmable wired zones (16 zones with our unique zone doubling
option)
- 16 fully
programmable wired zones with our OMNI-EXP8 - 8 hardwired zone expander
(32 zones with our unique zone doubling option)
- 48 total
zones with wireless
- Operates
with FBII International wireless devices
- Supports
eight 4-button wireless keys without taking up any zones
- Four totally
programmable trigger outputs on board
- Up to
20 fully programmable relay outputs
- Built-in
multilingual support for: English, Italian, Spanish, French, Dutch and
Portuguese
- System
Log retains the past 128
Events - New selectable SmartLog
- 64 User
Codes with four authorization levels
- Up to
4 partitions (3 partitions plus a common area)
- Auto-Arming
by partition
- Tamper
option by zone
- Built-in
Telephone Line Monitor
- Zones
may be configured as wired, wireless, E.O.L., D.E.O.L., N.O., N.C. or
Zone Doubling
- Follow
Me (Beeps audio format), domestic dialing
- Paging
- Inactivity
zones programmable by partition
Zones:
(Return to top)
- Eight
fully programmable EOL or DEOL supervised wired zones on main board
(up to 16 N.C. wired zones with our unique zone doubling option)
- Expansion
through plug in modules OPTIONS: model OMNI-EXP8 (eight zone wired expander),
OMNI-RF (48 zone wireless receiver)
- 16 traditional
EOL or DEOL supervised wired zones with OMNI-EXP8 zone expander module
(up to 32 N.C. wired zones with our unique zone doubling option)
- Zones
seven and eight may be programmed as fast zones (10 msec)
- Zone programming
selectable as EOL, DEOL, Zone Doubling, NO, NC
- Four Emergency
keypad conditions (Fire, Panic, Personal Emergency, Duress)
- Versatile
Zone Types:
- Controlled Zone types include: Instant, Exit/Entry, Interior, Day,
and keyswitch, with options for Fast Loop Response (zones 7 and 8),
Restore, Chime, Bypass and Dialer delay by zone
- 24 Hour Zone Types include: Fire, Burglary, Silent, Trouble, and Medical
- Programmable
central station reporting codes per zone
- Individual
reporting codes for Ambush, Panic, AC Loss, 24 Hour Test, Low Battery,
Open/Close, Trouble, Restore
- Cross
zoning
- Stay Delay
Mode provides an additional 40 seconds of dialer and/or siren delay
for special interior zones when armed in the stay mode
- Arm while
a zone is faulted option
- Restore
options: after siren time-out or follows loop
- Keyswitch
option per zone
- Chime
option by zone
- Inactivity
option by zone transmits signal to C.S. if zone has not been activated
in a preset time
- Multilingual
support selectable in several languages: English, Italian, Spanish,
French, Dutch, Portuguese, Chinese and Hebrew
Wireless
Operation:
(Return to top)
- 48 zone
wireless receiver (OMNI-RF) attaches directly to PCB
- Compatible
with FBII International wireless peripherals
- Dual diversity
antenna
- RF Jamming
Option
- Fully
supervised wireless displays complete zone status, low battery and RF
trouble by zone on all keypads
- System
supports eight wireless keys with each button individually programmable.
- Additionally,
each button can activate triggers/relays
- Wireless
remote keyfob transmits
- Open/Close
ID's for each remote
- Separate
RF Dings for arming and disarming with remote keys
Partitions:
- Three
partitions plus a common partition
- Zones,
User Codes, Keypads, and Remote Keyfobs may be assigned to each partition
- Extensive
cross partition support
- Separate
account and pager numbers for each partition
- Auto arming
by partition
- Inactivity
zones programmable by partition
- View all
partitions from a single keypad
- Partition
descriptor uniquely identifies each partition
- Multi
Partition mode allows secure operation of the system through any keypad
by authorized users
- Arm/Disarm
all partitions through a single keypad by authorized user
- Partition
Status keypad mode
Outputs:
(Return to top)
- Four (inverted)
voltage level output triggers on board and up to 20 Relays programmable
as follows: Burg Siren, Fire Siren, Partition Armed, Partition Ready,
Entry Delay, Exit Delay, Armed Instant, Armed Stay, Sounder On, Chime,
Line Seize, Phone Fail, AC Loss, Low Battery, 24hr. Zone Trouble, 24hr.
Zone Alarm, Instant Zone Fault, Delay Zone Fault, Interior Zone Fault,
Zone Tamper, RF Low Battery, RF Supervision, Communication Failure,
Keypad Tamper*, Duress Code*, Panic Key*, Memory of Alarm Strobe, Trigger
Zone*, Shock Sensor reset*, CS Test*, Alarm/Restore, 2 way voice, Momentary
(seconds), Momentary (minutes), Toggle (on/off)
*Outputs/relays programmable duration in seconds and minutes
for each partition
- Supports
up to 20 relays per system (5 per XL4705 external relay module)
- Relays
and triggers can be linked to zones, wireless remote keyfobs, keypad
emergency and system conditions
- Select
time duration for momentary conditions
User
Codes:
- 64 User
Codes, with four authorization levels
- 4 or 6
digit user codes
- Programmable
Open/Close ID's for each user
- Programmable
access to partitions for each user
- Option
to transmit O/C signals by user
- Ambush/Duress
and Door Strike codes
- Arm/Disarm
all partitions through any keypad by authorized users
- Quick
arming, Quick forced arming, Quick bypass options
- Arm only
code
- Paging
option by user
Additional
Features:
(Return to top)
- Cancel
Code feature, with siren verify option
- Dual entry
delay timers
- Installer
Walk Test feature
- Telephone
Line Monitor
- Real time
clock with reminder when time needs to be reset
- Siren
Test option, Smoke Detector reset and verification options
- Separate
alarm cutoff times for BURG and FIRE siren
- Programmable
entry/delay times, and siren lockout feature
- Intermittent
sensor shutdown option
- AC Based
Real Time Clock (50/60hz selectable)
- Siren
Supervision
- Busy Tone
Detection
- End User
Chime selection
- System
stabilization mode prevents false alarms during power-up
- Recent
Close and Exit Error options
- Keypad
Tamper function with optional C.S. transmission
- Keypad
Lockout Option
- Quick
Exit
- Arm while
a zone is faulted
- Option
to display zone status upon entry delay
- Programmable
Dialer Attempts programmable between 1-16
- LED Extinguish
option
- AC/LB
sounder disable option
- Display
bypassed zones during armed state
- Chime
on/off option through keypad
- Single
Key Arming Options by pressing either the "Stay" or "Instant"
key on all FBII keypads, or by using the Chatbak-V or wireless remotes
- Auto stay
option
- Auto-unbypass
option
- Flexible
system test timers (1, 7, 27, 60, 90 days) with options for test by
time, event or both. Additional one hour test time option for high security
applications
SmartLog:
- FBII's
unique SmartLog option allows you to choose the events to be stored
in memory
- Panel
retains past 128 events
- 90% or
100% full indication of system log transmitted to C.S.
- System
log viewable locally at LCD keypad or uploaded to Alarm Company
- Date (DD/MM
or MM/DD) and time (24hr. or AM/PM) option
- End User
view option
Keypads
(Return to top)
- Supports
up to 12 keypads per system (LED,
- Fixed
word LCD, and custom language programmable LCD)
- LED keypad
displays status of each individual zone, with indications of Alarm,
Trouble, Tamper, Stay, Bypass, Instant, Power and Not Ready conditions
- Fixed
word LCD keypad displays status of each zone, with indications of Alarm,
Fire, Trouble, Tamper, Bypass, Page, RF Supervision, Canceled, Chime,
Phone, Test, AC, Battery, and Not Ready conditions
- Custom
language LCD keypads display complete system status, in 2 line by 16
character SupertwistT display for easy viewing
- All keypads
available in many languages. Please contact your nearest distributor
for details
Programming/Remote
Operations:
- On-site
programming directly through keypads
- Remote
programming through WindowsT Downloader
- Security
features include special CSID and Installer codes, callback number,
default lockout feature and option to inhibit keypad programming
- On-line
and unattended downloading
- Up/Download
remotely even in the presence of fax/answering machines
- Remote
operations can be performed through single or a two call method
- Remote
operations include: arm, disarm, bypass zones, change user codes, read
system status, view event log and more
Central
Station Communications:
(Return to top)
- Dual central
station telephone numbers for each partition
- Two CS
account numbers (3 or 4 digits) for each partition
- Pulse
or DTMF dialing options
- Pulse
formats include 3x1, 4x1, 4x2,
Expanded: Speeds 10, 20, 40PPS with or without parity
- FBII Superfast,
Ademco Express 4x1, and 4x2 formats, Ademco CID format
- Split
and Dual reporting option for each partition
- Sonalert
ringback feature
- Follow
me (domestic dialing), paging, beeps audio formats
Power
Specifications:
- Watchdog
circuitry insures integrity of microprocessor
- Total
Aux. power: 500mA. regulated
- Transformer:
16.5V 40VA
- Alarm
Power: 1 Amp
Listings:
(Return to top)
- CE, TBR21
and Austel
- Pending
ANPI and UL
|