Features:

  • Eight zone EEPROM Control Communicator
  • Wired or multiplex expansion capability
  • 72 zone capacity through multiplex expansion
  • Partitioning (up to eight separate subsystems). Seven partitions plus a common area
  • Zone grouping capability within partitions
  • 64 user codes with seven authorization levels by user code
  • Keypad and remote programming
  • Upload/download/remote commands with answering machine override
  • Choice of LCD or LED keypads
  • System log retains past 128 events with option to automatically transmit log to remote or local printer
  • Fuseless design eliminates unnecessary service calls
  • Installer lockout option

New Features:

  • Master keypad showing armed/disarmed status for all partitions – LED or LCD
  • Auto arming by day, by partition
  • A single program question enabling all even zones to be tamper zones for all odd zones
  • A common area partition
  • Up to 40 programmable relays

Programming
(Return to top)

  • On site programming directly through keypad (LED or LCD)
  • Remote programming through PC downloader (7700)
  • Optional default lockout feature prevents hostile account takeovers
  • Option to inhibit keypad programming
  • Local programming secured through installer code
  • EEPROM memory retains programmable features and current status even during total power loss
  • Factory default characteristics simplify installation

Additional Features:

  • Programmable dialer and bell lockout feature
  • Accurate real time clock, time programmable by installer or authorized user
  • Flexible system test function with programmable frequency (12 hour, 24 hour or weekly transmission), and selectable time of day
  • Two programmable entry/exit delay times
  • CS reporting option to verify remote download request
  • Sounder ringback, and siren test at arming options
  • Auto-unbypass option
  • Four programmable keypad emergency conditions

Multiplex Capability:

  • Multiplex zone expansion option through 7120 module
  • System supports two wire bus capable of 64 points of protection
  • Two wire multiplex bus provides power and supervised data path between the control panel and the multiplex accessories
  • Multiplex accessories available; one, two or eight point modules for interfacing conventional alarm sensors to multiplex bus
  • Convenient two conductor wiring of multiplex loops for easy installation
  • Programmable zone characteristics for each multiplex point
  • PID format simplifies programming and provides complete reporting

Partitions:

  • Seven partitions with a common area partition
  • Each will contain a primary & secondary Central Station account number
  • Zones and keypads are assigned to the desired partition
  • User codes can be assigned to multiple partitions
  • Partition descriptor, 16 characters, uniquely identifies each subsystem
  • Multi partition feature allows secure operation of the system through any keypad by authorized users
  • Arm or Disarm all partitions through a single keypad by authorized user
  • Authorized users can alter partition assignments through the keypad
  • Auto arming by partition
  • Partition status keypad mode

System Log:

  • Panel retains activity log (128 events max)
  • System log viewable locally at LCD keypad or from Alarm Company
  • Programmable transfer of system activity to a remote or local* printer, automatically on either a daily, weekly or monthly basis

*Local printer requires 7130 module

Outputs:

  • Trigger outputs (eight voltage leveltriggers)
  • 40 Programmable Relays

Zones:
(Return to top)

  • Eight fully programmable EOL supervised wired zones on circuit board
  • Expansion through plug in module Options: model 7105 (eight zone wired expander), 7120 (multiplex bus expander, 64 points)
  • Zone programming flexibility including type and reporting characteristics
  • Programmable 16 character descriptors for each of 72 zones or points
  • Selectable alarm (16) and trouble (8) types
  • Programmable Central Station reporting & restore codes by zone
  • Keyswitch capability through any zone
  • Chime option by zone
  • Pulse count option by zone
  • Commands to view zone descriptions onLCD keypad
  • Zone grouping capability allows creation of groups within each partition for the
  • purpose of group bypass and alarm transmission

Remote Operations:

  • Patented answering machine override (AMD) for secure communications
  • Programmable callback feature prevents unauthorized access
  • Remote Downloading and uploading, from Alarm Company location
  • Interactive programming sessions permit control panel to remain on-line with the downloading computer during remote communications
  • Remotely arm, disarm, bypass, read system status, and device control

User Codes:
(Return to top)

  • 64 user codes, with 7 authorization levels
  • 4 digit or 7 digit user codes, system wide option
  • Programmable Open/Close ID’s for each user
  • Programmable partition access by user, access to partitions
  • Option to transmit O/C signals by user by partition
  • Ambush code capability
  • Arm or disarm all partitions through any keypad by authorized users
  • Quick arm, bypass, forced arming commands available
  • Arm only code

Central Station Communications:
(Return to top)

  • Dual central station telephone numbers for each partition
  • 2 CS account numbers (3 or 4 digits)
  • Transmission speeds include 10PPS, 20PPS, 40PPS, 4x2, FBII Superfast, BFSK, ADEMCO Express and Point ID formats
  • Pulse, Touch-Tone, or adaptive dialing (tone backed up by pulse)
  • Dial tone detection option
  • Installer options for each of the remote command capabilities

Keypads

  • Up to 16 per system, (LED or LCD) easy to install 4 wire devices may require auxiliary power supply
  • LCD keypad features easy to read 2 line with illuminated keys
  • LED keypad displays zone status communication and power indicators

Power Specifications:

  • Watchdog circuitry insures integrity of microprocessor
  • 24 hour battery load test and continuous low battery monitoring
  • Total Aux Power: 12 VDC, Regulated @ 900 mA
  • Keypad current = 250 mA, max., four-wire
    Smoke detector current = 150 mA max.
  • Aux current = 500 mA max. if keypad and smoke detector power is used, or 900 mA max. if keypad and smokepower is not used
  • Alarm Power: 12 VDC, Regulated @ 2 Amps

Listings:*
(Return to top)

  • UL Household Combination Burglary/Fire (XL-4)

 