| Features:
- Eight
zone EEPROM Control Communicator
- Wired
or multiplex expansion capability
- 72
zone capacity through multiplex expansion
- Partitioning
(up to eight separate subsystems). Seven partitions plus a common
area
- Zone
grouping capability within partitions
- 64
user codes with seven authorization levels by user code
- Keypad
and remote programming
- Upload/download/remote
commands with answering machine override
- Choice
of LCD or LED keypads
- System
log retains past 128 events with option to automatically transmit
log to remote or local printer
- Fuseless
design eliminates unnecessary service calls
- Installer
lockout option
New
Features:
- Master
keypad showing armed/disarmed status for all partitions – LED
or LCD
- Auto
arming by day, by partition
- A
single program question enabling all even zones to be tamper zones
for all odd zones
- A
common area partition
- Up
to 40 programmable relays
Programming
(Return to top)
- On
site programming directly through keypad (LED or LCD)
- Remote
programming through PC downloader (7700)
- Optional
default lockout feature prevents hostile account takeovers
- Option
to inhibit keypad programming
- Local
programming secured through installer code
- EEPROM
memory retains programmable features and current status even during
total power loss
- Factory
default characteristics simplify installation
Additional
Features:
- Programmable
dialer and bell lockout feature
- Accurate
real time clock, time programmable by installer or authorized
user
- Flexible
system test function with programmable frequency (12 hour, 24
hour or weekly transmission), and selectable time of day
- Two
programmable entry/exit delay times
- CS
reporting option to verify remote download request
- Sounder
ringback, and siren test at arming options
- Auto-unbypass
option
- Four
programmable keypad emergency conditions
Multiplex
Capability:
- Multiplex
zone expansion option through 7120 module
- System
supports two wire bus capable of 64 points of protection
- Two
wire multiplex bus provides power and supervised data path between
the control panel and the multiplex accessories
- Multiplex
accessories available; one, two or eight point modules for interfacing
conventional alarm sensors to multiplex bus
- Convenient
two conductor wiring of multiplex loops for easy installation
- Programmable
zone characteristics for each multiplex point
- PID
format simplifies programming and provides complete reporting
Partitions:
- Seven
partitions with a common area partition
- Each
will contain a primary & secondary Central Station account
number
- Zones
and keypads are assigned to the desired partition
- User
codes can be assigned to multiple partitions
- Partition
descriptor, 16 characters, uniquely identifies each subsystem
- Multi
partition feature allows secure operation of the system through
any keypad by authorized users
- Arm
or Disarm all partitions through a single keypad by authorized
user
- Authorized
users can alter partition assignments through the keypad
- Auto
arming by partition
- Partition
status keypad mode
System
Log:
- Panel
retains activity log (128 events max)
- System
log viewable locally at LCD keypad or from Alarm Company
- Programmable
transfer of system activity to a remote or local* printer, automatically
on either a daily, weekly or monthly basis
*Local
printer requires 7130 module
Outputs:
- Trigger
outputs (eight voltage leveltriggers)
- 40
Programmable Relays
Zones:
(Return to top)
- Eight
fully programmable EOL supervised wired zones on circuit board
- Expansion
through plug in module Options: model 7105 (eight zone wired expander),
7120 (multiplex bus expander, 64 points)
- Zone
programming flexibility including type and reporting characteristics
- Programmable
16 character descriptors for each of 72 zones or points
- Selectable
alarm (16) and trouble (8) types
- Programmable
Central Station reporting & restore codes by zone
- Keyswitch
capability through any zone
- Chime
option by zone
- Pulse
count option by zone
- Commands
to view zone descriptions onLCD keypad
- Zone
grouping capability allows creation of groups within each partition
for the
- purpose
of group bypass and alarm transmission
Remote
Operations:
- Patented
answering machine override (AMD) for secure communications
- Programmable
callback feature prevents unauthorized access
- Remote
Downloading and uploading, from Alarm Company location
- Interactive
programming sessions permit control panel to remain on-line with
the downloading computer during remote communications
- Remotely
arm, disarm, bypass, read system status, and device control
User
Codes:
(Return to
top)
- 64
user codes, with 7 authorization levels
- 4
digit or 7 digit user codes, system wide option
- Programmable
Open/Close ID’s for each user
- Programmable
partition access by user, access to partitions
- Option
to transmit O/C signals by user by partition
- Ambush
code capability
- Arm
or disarm all partitions through any keypad by authorized users
- Quick
arm, bypass, forced arming commands available
- Arm
only code
Central
Station Communications:
(Return to top)
- Dual
central station telephone numbers for each partition
- 2
CS account numbers (3 or 4 digits)
- Transmission
speeds include 10PPS, 20PPS, 40PPS, 4x2, FBII Superfast, BFSK,
ADEMCO Express and Point ID formats
- Pulse,
Touch-Tone, or adaptive dialing (tone backed up by pulse)
- Dial
tone detection option
- Installer
options for each of the remote command capabilities
Keypads
- Up
to 16 per system, (LED or LCD) easy to install 4 wire devices
may require auxiliary power supply
- LCD
keypad features easy to read 2 line with illuminated keys
- LED
keypad displays zone status communication and power indicators
Power
Specifications:
- Watchdog
circuitry insures integrity of microprocessor
- 24
hour battery load test and continuous low battery monitoring
- Total
Aux Power: 12 VDC, Regulated @ 900 mA
- Keypad
current = 250 mA, max., four-wire
Smoke detector current = 150 mA max.
- Aux
current = 500 mA max. if keypad and smoke detector power is used,
or 900 mA max. if keypad and smokepower is not used
- Alarm
Power: 12 VDC, Regulated @ 2 Amps
Listings:*
(Return
to top)
- UL
Household Combination Burglary/Fire (XL-4)
|